Underground XLPE Power Cable 0.6/1kv - Direct Burial HDPE-Jacketed Cable for Grids & Solar Farms

Still deciding? Get samples of $ !
Order Sample

Product Description

📋

Basic Specifications

Model NO.
YJY YJV WDZ-YJY WDZ-YJV
Current
DC & AC
Insulation
XLPE
Sheath Material
PE / LSOH
Material Shape
Round Wire
Wire Core
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS
Color
White/Black
MOQ
500m
HS Code
8544492100
📦

Packaging & Delivery

Package Size
110.00cm * 110.00cm * 75.00cm
Gross Weight
800.000kg
Package Type
Wooden Steel Drum
🛡️

Product Description

Product Name: YJY XLPE insulation LSOH Sheathed Flame retardant Power Cable

Constructions:

  • Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2
  • Insulation: XLPE/A
  • Inner Covering: LSOH
  • Sheath: LSOH, Black

Applications:

Widely used for tall buildings, hospitals, theaters, power stations, metro tunnels, petrochemical industries, and other special environments requiring low smoke, zero halogen (LSOH), and fire safety standards.

Technical Standards:

  • International: IEC 60502, IEC 60227, IEC 60331, IEC 601034
  • National Standards: GB/T 12706-91, GB306.1-2001, GB/T18380.3-2001
  • Third-party Certifications: CE, CCC, KEMA, BS, DIN, ICEA
📊

Technical Data Sheet

Rated Voltage0.6 kV
Max. Conductor Temp.Normal: 90°C; Short circuit (5s): Max 250°C
Min. Ambient Temp.Pre-heating required if below 0°C
Bending Radius (Single-core)20(d+D)±5%
Bending Radius (Multi-core)15(d+D)±5%
Flame RetardancyLSOH (Low Smoke Zero Halogen)
🖼️

Product Gallery

Frequently Asked Questions

What is the main benefit of XLPE insulation in power cables?
XLPE (Cross-linked Polyethylene) provides superior thermal, mechanical, and electrical properties, allowing the cable to handle higher conductor temperatures (up to 90°C) and offering excellent chemical resistance.
Why is LSOH (Low Smoke Zero Halogen) sheathing important?
LSOH materials significantly reduce the amount of toxic and corrosive gas emitted during combustion. This makes them ideal for enclosed public spaces like hospitals and tunnels where smoke visibility and safety are critical.
What is the rated voltage for the YJY series cables?
The YJY series power cables are designed for a rated voltage of 0.6/1 kV, suitable for most industrial and commercial power distribution applications.
Can these cables be used in short-circuit conditions?
Yes, the cables are designed to withstand a maximum conductor temperature of 250°C during a short circuit lasting no more than 5 seconds.
Does the cable require pre-heating during installation?
The cable should be pre-heated if the ambient temperature is below 0°C to prevent damage to the insulation and sheath during the bending and laying process.
What standards do these power cables comply with?
They comply with international standards including IEC 60502, IEC 60331, and IEC 60228, as well as various national certifications like CCC and CE.